Documentation

Workshop & Inspections

Chapter of the EVISYS user manual for rental operations.

On this page

Workshop & Inspections

Purpose {#purpose}

Workshop tickets for repairs and formal equipment inspections (DGUV, UVV, etc.).

Navigation: Sidebar Workshop → /app/workshop

Permissions: workshop.report (report — in all default roles), workshop.manage (edit, Workshop role), inspection.run (inspect), inspection.settings (inspection types), inspection.release (release)

Notifications for new tickets and open/overdue inspections go to users with workshop.manage (Workshop role, plus Administrator).

Workshop overview {#workshop-overview}

/app/workshop shows:

  • Open workshop tickets
  • Due and in-progress inspections
  • Filter by status and priority

Report a workshop ticket {#report-a-workshop-ticket}

From inventory {#from-inventory}

  1. Open equipment or item
  2. Report to workshop
  3. Description, priority, optional photos/attachments

From workshop {#from-workshop}

  1. Workshop → New ticket or scan
  2. Assign equipment (search or scan)

Permission: workshop.report

Edit workshop ticket {#edit-workshop-ticket}

/app/workshop/tickets/:id

Action Description
Assignee Assign the ticket to a person (or Unassigned)
Notes Document progress
Attachments Photos, invoices
Change status Open → In progress → Done
Complete repair Equipment back to In warehouse
Dispose Total loss — archive equipment

Permission: workshop.manage

Workshop scan {#workshop-scan}

/app/workshop/scan — scan equipment to quickly open or create a ticket.

Inspections {#inspections}

EVISYS supports recurring and event-based inspections with documented inspection steps.

Configure inspection types {#configure-inspection-types}

/app/workshop/inspection-settings

Element Description
Inspection type e.g. “DGUV V3”, “Visual truss inspection”
Inspection steps Checklist with required fields
Trigger Periodic, after rental, manual
Interval e.g. every 12 months

Permission: inspection.settings

Run an inspection {#run-an-inspection}

  1. Open due inspection in workshop overview or on equipment
  2. /app/workshop/inspections/:id — Start inspection
  3. Complete all steps (yes/no, readings, photos)
  4. Complete — on pass: equipment is released; this requires a saved signature under signature
  5. On fail: workshop ticket or status Defective

Permission: inspection.run

Release inspection {#release-inspection}

Some tenants require a second person for release (inspection.release).

Inspection PDF {#inspection-pdf}

Completed inspections can be exported as PDF: /app/workshop/inspections/:id/pdf

Compliance notes {#compliance-notes}

The app shows validation hints for incomplete documentation (e.g. missing readings, required photos). Inspection records should meet your safety officer’s requirements.

Instrument import (BENNING) {#instrument-import-benning}

Navigation: /app/workshop/instrument-import

Workflow for PAT test instruments (BENNING PC-Win ST 750–760):

  1. Export due devices as a BENNING .db file for the SD card
  2. Run the test on the instrument
  3. Import the results back

Running an inspection can wait in Instrument mode for the import from the test instrument. Unsupported DB versions are rejected with a clear error message.

Inspection calendar {#inspection-calendar}

/app/workshop/calendar — overview of due and planned inspections by date. Color coding by urgency.

Automatic reminders {#automatic-reminders}

The system can send notifications when inspections are due. Email settings: notifications.

Equipment lifecycle {#equipment-lifecycle}

On equipment detail (/app/inventory/equipment/:id), the timeline shows all inspections, workshop events, and rentals chronologically. Archived equipment no longer appears in workshop selection lists — see archive.

Common issues {#common-issues}

Problem Solution
Cannot complete inspection Fill all required steps; save a signature in account settings
Equipment blocked Maintenance status until inspection complete
No inspection types visible inspection.settings — admin must configure
BENNING import fails Check the DB version / export template

Last updated: November 2026